Temperature Data Loggers
|
|
Model # |
Download Type |
Temperature Range |
Wireless Range |
|
Wireless |
-22 to 122F
-30 to 50C |
Up to 300 ft. NLOS
1000 ft. LOS |
|
Wireless |
-40 to 300F |
Up to 300 ft. NLOS
1000 ft. LOS |
| Dickson Multipurpose Temperature
Data Logger |
|
Model # |
Download Type / Alarm |
Temperature Range / Accuracy |
Remote Temperature Range |
|
USB / Visual |
-10 to 176F /
1.2F
-23 to 80C /
0.7C |
|
|
USB / Visual |
-10 to 176F /
1.8F
-23 to 80C /
1.0C |
-300 to 500F
-300 to 2000F (w/optional A203 Probe) |
| Dickson LCD Temperature Display
Data Loggers |
|
Model # |
Network
Connectivity / Probe |
Temperature Accuracy |
Temperature Range |
|
MP100 / Yes |
0.8F / 0.5C |
-4 to 158F / -20 to 70C |
|
MP100 / Yes |
1.8F / 1.0C
*Range with standard K-TC Probe: -300 to +500°F (-184 to +260°C)
|
Internal: -4 to 158F / -20 to 70C
Remote: Full Range using A203 K-TC Probe: -300 to +2000°F (-184
to +1093°C) |
|
MP100 / Yes (2) |
1.8F / 1.0C |
Range with standard K-Thermocouple Probe: -300
to +500°F (-184 to +260°C) |
|
MP100 / Yes |
0.5F / 0.3C |
-50 to 350F / -45 to 176C |
|
Ethernet / Yes |
1.8F / 1.0C |
-300 to 2000F / -184 to 1093C |
|
Ethernet / Yes (2) |
1.8F / 1.0C |
-300 to 2000F / -184 to 1093C |
Dickson Flat Panel LCD Temperature
Data Logger - Paperless Recorder |
|
Model # |
Temperature Accuracy |
Temperature Range |
Remote Probe / Alarm / LCD Display |
|
±1.2F (±0.7C) |
0 to 100F
-10 to 40C
0 to 50F |
No / Yes / 4.5" x 3.4" |
|
±1.2F (±0.7C) |
-20 to 80F/C
-40 to 140F/C
0 to 100F/C
0 to 150F/C
0 to 250F
0 to 300F |
Yes / Yes/ 4.5" x 3.4" |
|
±.5F (±0.3C) |
-20 to 80F/C
0 to 100F
0 to 150F
|
Yes / Yes / 4.5" x 3.4" |
| High Temperature, Stainless Steel,
Waterproof Data Loggers
|
|
Model # |
Temperature Accuracy |
Temperature Range |
Piercing Probe |
|
±1.8F (±1C) over entire range |
-40 to 257F / -40 to 125C
|
|
|
±1.8F (±1C) over entire range |
-40 to 257F / -40 to 125C |
2.36" x 0.19" DIA |
|
±1.8F (±1C) over entire range |
-40 to 257F / -40 to 125C |
4.88" x 0.11" DIA |
| Temp Logger, ±1.2F, 32K Data Points,
Visual Alarm, Small Display |
|
Model # |
Digital Display |
Temperature Range |
Start/Stop - Push to Start |
|
Yes |
-4 to 158F / -20 to 70C |
No - Yes |
|
Yes |
-4 to 158F / -20 to 70C |
Yes - No |
Vaccine Specific
Temperature Data Loggers |
|
Model # |
Display |
Temperature Range |
Temp. Accuracy |
|
Medium |
Internal: / External:
-4 to 158F / -20 to 158F
-20 to 70C / -29 to 70C
|
1.8F / 1C |
|
Medium |
Internal: / External:
-4 to 158F / -20 to 158F
-20 to 70C / -29 to 70C
|
1.8F / 1C |
Economical Temperature Data Logger |
|
Model # |
Temperature Accuracy |
Temperature Range |
Ambient Operating Conditions |
|
±2.25F (+14 to +176F) |
-40 to 176F / -40 to 80C |
-40 to +176°F (-40 to +80°C), 0 to 95% RH (non-condensing) |
Super Compact and Economical Temperature
Data Loggers |
|
Model # |
Temperature Accuracy |
Temperature Range |
Ambient Operating Conditions |
|
±1.8F (±1C)
over range -4 to +158F (-20 to +70C) |
-4 to 158F / -20 to 70C |
4 to +158°F (-20 to +70°C), 0 to 95%
RH (non-condensing) |
Dickson WT100 Wireless Wizard Temperature
Wireless Data Logger
Forget the bothers and delays of downloading data--
This real-time monitoring solution saves hundreds of staff hours each
year!
The world’s first reliable wireless data logger
• Up to 9-day data backup storage with failsafe Dickson Data-Keep™
• Easy setup and network monitoring with WIZARD SIGNAL SENSOR™
• Easy-to-use software manages all loggers from one desktop
• User-adjustable sampling rate
• 6 month battery and battery indicator alarm
Note: The Wizard is currently available as a North America compliant
solution. A worldwide solution will be available in 2009. The Wizard
is approved for Windows XP, not with Vista.
Wireless Range (Distance):
Up to 300 feet NLOS (Non-Line-of-Sight)
1000 feet LOS (Line-of-Sight)
Notes:
The WT100 Logger reads temperature conditions and sends data back to
the Receiver at regular intervals.
Data is stored in each remote sensor so loss of wireless connection
does not result in loss of recorded values.
Sample Interval:
User Selectable from 30 Seconds to 15 Minutes in 1 Second Intervals
Transmissions Frequency:
User Selectable: 5, 10 or 15 minute intervals
Power:
2 AA Batteries
Alarm Type:
Displays Alarm Conditions in Wizard Software: High/Low Alarm, Low Battery,
Calibration Due, Lost Communication; Pop-up Notification
Battery Life (Avg):
1-Year at 5-Minute Sample Rate and 15 Minute Transmission Frequency
Channels:
1 (Temperature)
Data Capacity:
1728 - Data stored on Logger only when communications fail.
Download Type:
Wireless
Temperature Range:
-22 to 122F
-30 to 50C
Temperature Accuracy:
+/-1.2F from +20 to 122F; +/-1.8 remaining
Temperature Sensor:
Digital Temperature Sensor
Software Features:
Logged data written to database upon transmission.
View multiple loggers on single graph.
View multiple graphs simultaneously.
Quick and easy export of graphs and logged data to Excel.
View logger status of all loggers in one easy table.
Software Required:
Dickson Wizard Software (Included with WR100)
Wireless Range:
Up to 300 ft. NLOS
1000 ft. LOS
Radio Frequency:
900 MHz range (902 to 928 MHz)
Signal Strength:
Min +27 dBm (50mW)
Output Signal:
4800 Baud Serial Data
Ambient Operating Conditions:
-22 to 122F (-30 to 50C); 0 to 95% RH non-condensing
Approvals:
RHOS, FCC Part 15 Compliant (Pending)(Pending)
Software PC Requirements:
Approved for MS Windows XP.
Power Status Indicator:
Red LED: Blinks Red 3x when powered on. Blinks Red 1x when taking a
reading and 2x when sending or Looking for Signal.
Storage Conditions:
-22 to 158F (-30 to 70C); 0 to 95% RH non-condensing
Response Time:
30 Seconds to 63% FS
Resolution:
Logger: 0.1 Deg.
Antenna:
User Replaceable Fully Articulating
Enclosure:
Black; ABS Plastic Clam Shell
Mounting:
Free Standing or Wall Mount with Keyhole
Dimensions (Inches/cm):
3.4" x 3.4" x 1.2" (8.6 x 8.6 x 3.0cm)
Weight:
6.2oz (175g)
Units / Pkg:
1
Included Accessories:
2AA Batteries, Manual
Calibration:
Factory: NIST Calibration
IP Rating:
20
A.K.A.:
Wireless, Wireless Logger, Dickson Logger, Dickson Wireless, Wireless
Monitoring, Temperature, Temperature Logger, Temperature Monitoring,
Humidity, Humidity Monitoring, Humidity Logger,
Key Features:
1. Easy to setup and use
2. Cost efficient
3. Real-time alarms of out-of-range conditions right at your workstation
Alarm:
Yes
Accessories:
WR100 - Receiver and Wizard Software
WA100 - Repeater
WS100 - Signal Sensor
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
WT120 Wireless Wizard Temperature Wireless Data Logger
Forget the bothers and delays of downloading data--
This real-time monitoring solution saves hundreds of staff hours each
year!
The world’s first reliable wireless data logger--
• Up to 9-day data backup storage with failsafe Dickson Data-Keep™
• Easy setup and network monitoring with WIZARD SIGNAL SENSOR™
• Easy-to-use software manages all loggers from one desktop
• Remote thermistor probe
• User-adjustable sampling rate
• 6 month battery and battery indicator alarm
Note:The Wizard is currently available as a North America compliant solution.
A worldwide solution will be available in 2009. The Wizard is approved
for Windows XP, not with Vista.
Wireless Range (Distance):
Up to 300 feet NLOS (Non-Line-of-Sight)
1000 feet LOS (Line-of-Sight)
Notes:
The WT120 Logger reads temperature conditions and sends data back to
the Receiver at regular intervals.
Data is stored in each remote sensor so loss of wireless connection
does not result in loss of recorded values.
Sample Interval:
User Selectable from 30 Seconds to 15 Minutes in 1 Second Intervals
Transmissions Frequency:
User Selectable: 5, 10 or 15 minute intervals
Power:
2 AA Batteries
Alarm Type:
Displays Alarm Conditions in Wizard Software: High/Low Alarm, Low Battery,
Calibration Due, Lost Communication; Pop-up Notification
Battery Life (Avg):
1-Year at 5-Minute Sample Rate and 15 Minute Transmission Frequency
Channels:
1 (Temperature Probe)
Data Capacity:
1728 (864 per channel) - Data stored on Logger only when communications
fail.
Download Type:
Wireless
Remote Probe Dimensions:
10 Feet Long with submersible tip
Remote Temperature Range:
-40 to 300F (-40 to 150C)
Remote Temperature Accuracy:
+/-1.2F from -20 to 220F; +/-3.0 remaining
Remote Sensor:
Thermistor
Software Features:
Logged data written to database upon transmission.
View multiple loggers on single graph.
View multiple graphs simultaneously.
Quick and easy export of graphs and logged data to Excel.
View logger status of all loggers in one easy table.
Software Required:
Dickson Wizard Software (Included with WR100 Receiver)
Wireless Range:
Up to 300 ft. NLOS
1000 ft. LOS
Radio Frequency:
900 MHz range (902 to 928 MHz)
Signal Strength:
Min +27 dBm (50mW)
Output Signal:
4800 Baud Serial Data
Ambient Operating Conditions:
-22 to 122F (-30 to 50C); 0 to 95% RH non-condensing
Approvals:
RHOS, FCC Part 15 Compliant(Pending)
Software PC Requirements:
Approved for MS Windows XP
Power Status Indicator:
Red LED: Blinks Red 3x when powered on. Blinks Red 1x when taking a
reading and 2x when sending or Looking for Signal.
Storage Conditions:
-22 to 158F (-30 to 70C); 0 to 95% RH non-condensing
Response Time:
30 Seconds to 63% FS
Resolution:
Logger: 0.1 Deg.
Antenna:
User Replaceable Fully Articulating
Enclosure:
Black; ABS Plastic Clam Shell
Mounting:
Free Standing or Wall Mount with Keyhole
Dimensions (Inches/cm):
3.4" x 3.4" x 1.2" (8.6 x 8.6 x 3.0cm)
Weight:
6.2oz (175g)
Units / Pkg:
1
Included Accessories:
2AA Batteries, Manual
Calibration:
Factory: NIST Calibration
IP Rating:
20
A.K.A.:
Wireless, Wireless Logger, Dickson Logger, Dickson Wireless, Wireless
Monitoring, Temperature, Temperature Logger, Temperature Monitoring,
Humidity, Humidity Monitoring, Humidity Logger,
Key Features:
1. Easy to setup and use
2. Cost efficient
3. Real-time alarms of out-of-range conditions right at your workstation
Alarm:
Yes
Remote Probe:
Yes
Temperature Range:
-40 to 300F
Accessories:
WR100 - Receiver and Wizard Software
WA100 - Repeater
WS100 - Signal Sensor
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SP125 Multipurpose Temperature Data Logger
The Ultimate in Versatility - this highly accurate data logger excels
in the widest range of applications – regulatory compliance, HVAC
balancing, warehouse mapping, process control, inventory storage, and
more.
Adapts to your application
• USB –enabled triple-speed downloading.
• 32KB storage.
• User-defined sampling rates.
• Battery-powered, compact and rugged—place it anywhere
Temperature Range:
-10 to 176F
-23 to 80C
Temperature Accuracy:
±1.2F (0.7C)
Temperature Sensor:
Internal Digital sensor
Ambient Operating Conditions:
-10 to 176F (-23 to 80C), 0 to 95% RH (non-condensing)
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Alarm Type:
LED flashes Red when High/Low Limits are met
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected Sample
Interval.
Power Source:
CR2450 lithium (user replaceable)
Power Status Indicator:
LED flashes green when sampling
Battery Life (Avg):
1-year
Resolution:
0.1F
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: NIST traceable
User Calibration w/ SW400:
Yes
DicksonWare™ Software Minimum Version Required:
10
Software Required:
A016
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or better; PC w/ 486 MHz or faster microprocessor,
16 MB RAM, 1 free USB root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
USB male series "A" plug to 5-pin male series "B"
mini plug, 6 ft (2 meters)
DicksonWare™ Computer Interface:
USB
Software Features:
Selectable Sample Interval, F/C Selectable, Wrap or Stop when Full, Delayed
Start, Real Time Monitoring and Much More.
Download Time:
1-minute when logger is full
Dimensions (Inches/cm):
3.1x2.1x0.9
7.9x5.4x2.2
Weight:
1.9 oz
53g
IP Rating:
IP20
Warranty:
12-Month Limited
Alarm:
Visual
Key Features:
1.One-Year Battery
2.Range -10 to 176F
3.High/Low LED Alarm
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Pro Series Data Logger,
Pro Logger, Pro Data Logger, Dickson Data Logger, Dickson Logger, Dickson
SP, Datalogger, Temperature Data Logger, Temperature Logger, Data Environment
Logger, K-Thermocouple Data Logger, K-TC Data Logger, Remote Probe Data
Logger, Remote Probe Logger, Thermocouple Data Logger, High Temperature
Data Logger, Two Channel Data Logger, SP120, Datalogger
Download Type:
USB
Temp. Accuracy:
1.2F
0.7C
Power:
Battery
Accessories:
A124 3V for USB Pro Series CR2450
A061 USB Download Cable Only - 6FT
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A715 Locking Wall Mount Case, Small
A713 Water-resistant Pouch, Soft, Small
SW400 Logger Calibration Software
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SP175 Multipurpose with Probe Temperature Data Logger
The Ultimate in Versatility - this highly accurate data logger excels
in a wide range of applications – laboratory, pharmaceutical, meat
and other food processing, and more.
Adapts to your application--
• K-Thermocouple probe
• USB-enabled triple-speed downloading.
• 32KB storage
• User-defined sampling rates
• Battery-powered, compact and rugged—place it anywhere.
Temperature Range:
-10 to 176F
-23 to 80C
Temperature Accuracy:
±1.8F (±1C)
Temperature Sensor:
Thermistor
Thermocouple
Remote Temperature Range:
-300 to 500F
-300 to 2000F (w/optional A203 Probe)
Remote Temperature Accuracy:
±1.8F
±1C
Remote Sensor:
Thermocouple (other K-TC probes available - see Accessories)
Ambient Operating Conditions:
-10 to 176F (-23 to 80C), 0 to 95% RH (non-condensing)
Alarm Type:
LED flashes Red when High/Low Limits are met
Data Capacity:
32512
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
CR2450 lithium (user replaceable)
Power Status Indicator:
LED flashes green when sampling
Battery Life (Avg):
1-year
Remote Probe Dimensions:
K-type bead wire with mini connector; Cable Length: 4’ (121cm);
extension cables available
Resolution:
0.1F
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: NIST traceable
User Calibration w/ SW400:
Yes
DicksonWare™ Software Minimum Version Required:
10
Software Required:
A016
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or higher; PC w/ 486 MHz or faster microprocessor,
16 MB RAM, 1 free USB root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
USB male series "A" plug to 5-pin male series "B"
mini plug, 6 ft (2 meters)
DicksonWare™ Computer Interface:
USB
Software Features:
Selectable Sample Interval, F/C Selectable, Wrap or Stop when Full,
Delayed Start, Real Time Monitoring and Much More.
Download Time:
1-minute when logger is full
Dimensions (Inches/cm):
3.1x2.1x0.9
7.9x5.4x2.2
Weight:
1.9 oz
53g
IP Rating:
IP20
Warranty:
12-Month Limited
Alarm:
Visual
Key Features:
1.One Year - User Replaceable Battery
2.Range -300 to 2000F
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Pro Series Data Logger,
Pro Logger, Pro Data Logger, Dickson Data Logger, Dickson Logger, Dickson
SP, Datalogger, Temperature Data Logger, Temperature Logger, Data Environment
Logger, K-Thermocouple Data Logger, K-TC Data Logger, Remote Probe Data
Logger, Remote Probe Logger, Thermocouple Data Logger, High Temperature
Data Logger, Two Channel Data Logger, SP120, Datalogger
Remote Probe:
Yes
Download Type:
USB
Temp. Accuracy:
1.8F
1.0C
Power:
Battery
Accessories:
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
A124 3V for USB Pro Series CR2450
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
A202 K-Thermocouple 100' Straight Extension Cable
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
D606 Angled Surface Temperature Probe w/ Mini Connector; -418 to 1200°F
(-250 to 649°C)
A715 Locking Wall Mount Case, Small
A713 Water-resistant Pouch, Soft, Small
SW400 Logger Calibration Software
A061 USB Download Cable Only - 6FT
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SM300 Time-Saver Temperature Data Logger
Only Download Data When You Need To–24/7 feedback through Min/Max
or Real-Time Display, bolstered by visual and audio high/low alarms.
Download Data Quickly!—
• USB-enabled triple-speed downloading
• FLASH memory card data transfer-capable
• +/-0.8F accuracy
• Jumbo display PLUS visual/audio alarms
Temperature Range:
-4 to 158F
-20 to 70C
Temperature Sensor:
Thermistor
Temperature Accuracy:
±0.8F (±.5C) for a temperature between +20 to +120F (-7
to +49C) ; ±1.8F (±1C) for all other temperaure ranges
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing
Download Type:
USB, Serial or Memory Card
Keypad Functions:
3 buttons with tactile feedback; Min/Max, Alarm, Download
Download Time:
1-Minute (USB); 3-Minutes (Serial)
Response Time:
2.5 minutes typical.
Display:
Medium
Display Update Rate:
10 Seconds under battery power; 1 second under AC power.
Display Dimensions:
2.0" x 1.375"
Display Min/Max:
Yes
Resolution:
0.1° From 0.0 to 999.9; 1° over 1000
Power Source:
Batteries, 4 AA Alkaline; AC adapter - optional (Input Voltage/Current:
120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A
Power Status Indicator:
LCD Display
Input Connections:
Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length:
6 feet)
Battery Life (Avg):
6-months
Battery Backup:
Yes with optional AC Adapter
Memory:
EEPROM, Removable Flash Storage Device - stores data from 1000+ Data
Loggers
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 or
10 second increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Alarm:
Audio/Visual
Approvals:
CE
Calibration:
Standard Dickson Certificate of Calibration
User Calibration w/ SW400:
Yes
Available Calibration Options:
User: zero point; Factory: zero point & span NIST traceable
Enclosure:
Polycarbonate
Mounting:
Wall mountable via keyhole slots
Included Accessories:
Batteries, instruction manual
DicksonWare™ Software Minimum Version Required:
8.0
DicksonWare™ PC/Software Requirements:
Windows® 98, 2000, and XP; PC with 486 MHz or better microprocessor,
16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB
root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
A015/A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A016/A026:
USB male series “A” plug to 5-pin male series “B ”
mini plug, 6 ’ (2 meters)
DicksonWare™ Computer Interface:
RS-232 serial (COM) port or USB
Units / Pkg:
1
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
Warranty:
12-Month Limited
IP Rating:
IP20
Key Features:
1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity & Flash Memory
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data
Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson
Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory
Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment
Logger, Flash Memory Card, Alarm, Datalogger
Network Connectivity:
MP100
Temp. Accuracy:
0.8F
0.5C
SD Memory Card:
Yes
Power:
Battery
Accessories:
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ SoftwareSerial Download Cable
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
A210 Removeable FLASH Storage Device
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
R006 "AA" Alkaline battery
R157 AC Adapter
SW400 Logger Calibration Software
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SM320 Time-Saver K-Thermocouple Probe Temperature Data Logger
Only Download Data When You Need To–24/7 feedback through Min/Max
or Real-Time Display, bolstered by visual and audio high/low alarms.
Download Data Quickly!—
• USB-enabled triple-speed downloading
• FLASH memory card data transfer-capable
• +/-0.8F accuracy
• K-Thermocouple Probe
• Jumbo display PLUS visual/audio alarms
Temperature Range:
Internal:
-4 to 158F
-20 to 70C
Remote:
Full Range using A203 K-TC Probe: -300 to +2000°F
(-184 to +1093°C)
Range with standard K-TC Probe: -300 to +500°F
(-184 to +260°C)
Temperature Sensor:
Thermistor
Thermocouple
Temperature Accuracy:
±1.8F (±1C)
Remote Temperature Range:
Full Range using A203 K-Thermocouple Probe: -300 to +2000°F (-184
to +1093°C)
Range with standard K-Thermocouple Probe: -300 to +500°F (-184 to
+260°C)
Remote Sensor:
4’ Teflon coated K-Thermocopule bead-wire probe with mini-connector
Remote Temperature Accuracy:
±1.8°F (±1°C) logger only
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing
Download Type:
USB, Serial or Memory Card
Download Time:
1-Minute (USB); 3-Minutes (Serial)
Keypad Functions:
3 buttons with tactile feedback; Min/Max, Alarm, Download
Response Time:
2.5 minutes typical
Display:
Medium
Display Update Rate:
10 Seconds under battery power; 1 second under AC power.
Display Dimensions:
2.0" x 1.375"
Display Min/Max:
Yes
Resolution:
0.1° From 0.0 to 999.9; 1° over 1000
Power Source:
Batteries, 4 AA Alkaline; AC adapter - optional (Input Voltage/Current:
120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A
Power Status Indicator:
LCD Display
Input Connections:
Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length:
6 feet)
Battery Life (Avg):
6-months
Battery Backup:
Yes with optional AC Adapter
Memory:
EEPROM, Removable Flash Storage Device - stores data from 1000+ Data
Loggers
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 or
10 second increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Alarm:
Audio/Visual
Approvals:
CE
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point, Factory: NIST traceable
User Calibration w/ SW400:
Yes
Enclosure:
Polycarbonate
Mounting:
Wall mountable via keyhole slots
Included Accessories:
Batteries, instruction manual
DicksonWare™ Software Minimum Version Required:
8.0
DicksonWare™ PC/Software Requirements:
Windows® 98, 2000, and XP; PC with 486 MHz or faster microprocessor,
16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB
root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
A015/A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A016/A026:
USB male series “A” plug to 5-pin male series “B”
mini plug, 6 ’ (2 meters)
DicksonWare™ Computer Interface:
RS-232 serial (COM) port or USB
Units / Pkg:
1
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity & Flash Memory
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data
Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson
Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory
Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment
Logger, Flash Memory Card, Alarm, K-Thermocouple Data Logger, K-TC Data
Logger, Remote Probe Data Logger, Remote Probe Logger, Thermocouple
Data Logger, High Temperature Data Logger, Two Channel Data Logger,
Datalogger
Remote Probe:
Yes
Remote Sensing Range:
-300 to +2000°F (w/A203 probe)
Network Connectivity:
MP100
Temp. Accuracy:
1.8F
1.0C
SD Memory Card:
Yes
Power:
Battery
Accessories:
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ Software Serial Download Cable
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
A210 Removeable FLASH Storage Device
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
R157 AC Adapter
SW400 Logger Calibration Software
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
R006 "AA" Alkaline battery
A202 K-Thermocouple 100' Straight Extension Cable
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SM325 Time-Saver Two-Probe Temperature Data Logger
Only Download Data When You Need To–24/7 feedback through Min/Max
or Real-Time Display, bolstered by visual and audio high/low alarms.
Download Data Quickly!—
• USB-enabled triple-speed downloading
• FLASH memory card data transfer-capable
• 2 K-Thermocouple Probe
• Jumbo display PLUS visual/audio alarms
Remote Temperature Range:
Full Range using A203 K-Thermocouple Probe: -300 to +2000°F (-184
to +1093°C)
Range with standard K-Thermocouple Probe: -300 to +500°F (-184 to
+260C)
Remote Sensor:
4’ Teflon coated K-Thermocopule bead-wire probe with mini-connector
Remote Temperature Accuracy:
±1.8°F (±1°C) logger only
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing
Download Type:
USB, Serial or Memory Card
Download Time:
1-Minute (USB); 3-Minutes (Serial)
Keypad Functions:
3 buttons with tactile feedback; Min/Max, Alarm, Download
Response Time:
1 minute to 63% of full scale, typical
Display:
Medium
Display Update Rate:
10 Seconds under battery power; 1 second under AC power.
Display Dimensions:
2.0" x 1.375"
Display Min/Max:
Yes
Resolution:
0.1° From 0.0 to 999.9; 1° over 1000
Power Source:
Batteries, 4 AA Alkaline; AC adapter - optional (Input Voltage/Current:
120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A
Power Status Indicator:
LCD Display
Input Connections:
Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length:
6 feet)
Battery Life (Avg):
6-months
Battery Backup:
Yes with optional AC Adapter
Memory:
EEPROM, Removable Flash Storage Device - stores data from 1000+ Data
Loggers
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 or
10 second increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Alarm:
Audio/Visual
Approvals:
CE
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point, Factory: NIST traceable
User Calibration w/ SW400:
Yes
Enclosure:
Polycarbonate
Mounting:
Wall mountable via keyhole slots
Included Accessories:
Batteries, instruction manual
DicksonWare™ Software Minimum Version Required:
8.0
DicksonWare™ PC/Software Requirements:
Windows® 98, 2000, and XP; PC with 486 MHz or better microprocessor,
16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB
root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
A015/A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A016/A026:
USB male series “A” plug to 5-pin male series “B”
mini plug, 6’ (2 meters)
DicksonWare™ Computer Interface:
RS-232 serial (COM) port or USB
Units / Pkg:
1
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity & Flash Memory
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data
Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson
Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory
Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment
Logger, Flash Memory Card, Alarm, K-Thermocouple Data Logger, K-TC Data
Logger, Remote Probe Data Logger, Remote Probe Logger, Thermocouple
Data Logger, High Temperature Data Logger, Two Channel Data Logger,
Datalogger
Remote Probe:
Yes(2)
Remote Sensing Range:
-300 to +2000°F (w/A203 probe)
Temperature Accuracy:
±1.8F (±1C)
Temperature Range:
Range with standard K-Thermocouple Probe: -300 to +500°F (-184 to
+260°C)
Network Connectivity:
MP100
Temp. Accuracy:
1.8F
1.0C
SD Memory Card:
Yes
Power:
Battery
Accessories:
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ Software Serial Download Cable
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
A210 Removeable FLASH Storage Device
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
R157 AC Adapter
SW400 Logger Calibration Software
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
R006 "AA" Alkaline battery
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
A202 K-Thermocouple 100' Straight Extension Cable
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Accessories:
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ Software Serial Download Cable
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
A210 Removeable FLASH Storage Device
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
R157 AC Adapter
SW400 Logger Calibration Software
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
R006 "AA" Alkaline battery
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
A202 K-Thermocouple 100' Straight Extension Cable
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SM420 Time-Saver RTD Probe Temperature Data Logger
High Accuracy RTD Probe-- designed for pharmaceutical FDA compliance
and other demanding applications.
Time-saving Data Management features-
• 24/7 feedback through Min/Max or Real-Time Display with visual/audio
alarms
• USB-enabled triple-speed data downloading
• FLASH memory card data transfer-capable
• +/-0.5F accuracy with RTD Probe
Remote Temperature Range:
Range with standard PRTD Probe: -50 to +350°F (-45 to +176°C)
Remote Sensor:
Platinum RTD w/6 ft. cable length and 2 inch stainless steel tip
Remote Temperature Accuracy:
±0.5°F (±0.28°C)
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing
Download Type:
USB, Serial or Memory Card
Download Time:
1-Minute (USB); 3-Minutes (Serial)
Keypad Functions:
3 buttons with tactile feedback; Min/Max, Alarm, Download
Response Time:
3 minutes typical
Display:
Medium
Display Update Rate:
10 Seconds under battery power; 1 second under AC power.
Display Dimensions:
2.0" x 1.375"
Display Min/Max:
Yes
Resolution:
0.1° From 0.0 to 999.9; 1° over 1000
Power Source:
Batteries, 4 AA Alkaline; AC adapter - optional (Input Voltage/Current:
120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A
Power Status Indicator:
LCD Display
Input Connections:
Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length:
6 feet)
Battery Life (Avg):
6-months
Battery Backup:
Yes with optional AC Adapter
Memory:
EEPROM, Removable Flash Storage Device - stores data from 1000+ Data
Loggers
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 or
10 second increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Alarm:
Audio/Visual
Approvals:
CE
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point, Factory: NIST traceable
User Calibration w/ SW400:
Yes
Enclosure:
Polycarbonate
Mounting:
Wall mountable via keyhole slots
Included Accessories:
Batteries, instruction manual
DicksonWare™ Software Minimum Version Required:
9.0
DicksonWare™ PC/Software Requirements:
Windows® 98, 2000, and XP; PC with 486 MHz or faster microprocessor,
16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB
root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
A015/A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A016/A026:
USB male series “A” plug to 5-pin male series “B”
mini plug, 6 ’ (2 meters)
DicksonWare™ Computer Interface:
RS-232 serial (COM) port or USB
Units / Pkg:
1
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity & Flash Memory
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data
Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson
Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory
Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment
Logger, Flash Memory Card, Alarm, K-Thermocouple Data Logger, K-TC Data
Logger, Remote Probe Data Logger, Remote Probe Logger, Thermocouple
Data Logger, High Temperature Data Logger, Two Channel Data Logger,
Datalogger, Platinum RTD
Remote Probe:
Yes
Remote Sensing Range:
-50 to +350°F
Temperature Accuracy:
±0.5F
±0.28C)
Temperature Range:
-50 to 350F
-45 to 176C
Network Connectivity:
MP100
Temp. Accuracy:
0.5F
0.3C
SD Memory Card:
Yes
Power:
Battery
Remote Probe Dimensions:
Metal tip: 2 inch length, .190 inch diameter; Cable: 6 foot length,
.110 diameter
Accessories:
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ Software Serial Download Cable
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
A210 Removeable FLASH Storage Device
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
R157 AC Adapter
SW400 Logger Calibration Software
R006 "AA" Alkaline battery
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SM720 Ethernet-Connect with Probe Temperature Data Logger
Manage all the data loggers in your network from one PC - connecting
data loggers to your Ethernet network is as easy as installing a printer!
Time-saving Data Management features-
• 24/7 feedback through Min/Max or Real-Time Display
• Visual/audio alarms
• Email alert capable
• K-thermocouple probe
Remote Temperature Range:
Full Range using A203 K-Thermocouple Probe: -300 to +2000°F (-184
to +1093°C)
Range with standard K-Thermocouple Probe: -300 to +500°F (-184 to
+260°C)
Remote Sensor:
4’ Teflon coated K-Thermocopule bead-wire probe with mini-connector
Remote Temperature Accuracy:
±1.8°F (±1°C) logger only
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing
Download Type:
USB, Serial or Standard Ethernet
Download Time:
1-Minute (USB); 3-Minutes (Serial); 2.0 Minutes (Ethernet)
Keypad Functions:
3 buttons with tactile feedback; Min/Max, Alarm, Save
Response Time:
2.5 minutes typical
Display:
Medium
Display Update Rate:
10 Seconds under battery power; 1 second under AC power.
Display Dimensions:
2.0" x 1.375"
Display Min/Max:
Yes
Resolution:
0.1° From 0.0 to 999.9; 1° over 1000
Power Source:
Battery (included/backup only), 1 9V; AC adapter (included)-(Input Voltage/Current:
120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A, Optional Universal
International Adapter Available
Power Status Indicator:
LCD Display
Input Connections:
Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length:
6 feet)
Battery Life (Avg):
3 Hours
Battery Backup:
Yes with AC Adapter
Memory:
EEPROM
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 or
10 second increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Alarm:
Audio/Visual
Approvals:
CE
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point, Factory: NIST traceable
User Calibration w/ SW400:
Yes
Enclosure:
Polycarbonate
Mounting:
Wall mountable via keyhole slots
Included Accessories:
Battery, instruction manual,AC adapter - (Input Voltage/Current: 120VAC/60Hz/16W;
Output Voltage/Current: 9VDC/1A
DicksonWare™ Software Minimum Version Required:
9.0 DicksonWare Secure Software Required
DicksonWare™ PC/Software Requirements:
Windows® 98, 2000, and XP; PC with 486 MHz or faster microprocessor,
16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB
root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A026:
USB male series “A” plug to 5-pin male series “B”
mini plug, 6 ’ (2 meters)
DicksonWare™ Computer Interface:
RS-232 serial (COM) port or USB
Units / Pkg:
1
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data
Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson
Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory
Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment
Logger, Flash Memory Card, Alarm, K-Thermocouple Data Logger, K-TC Data
Logger, Remote Probe Data Logger, Remote Probe Logger, Thermocouple
Data Logger, High Temperature Data Logger, Two Channel Data Logger,
Datalogger, Ethernet Data Logger
Remote Probe:
Yes
Remote Sensing Range:
-300 to +2000°F (w/A203 probe)
Network Connectivity:
Ethernet
Temperature Accuracy:
±1.8F (±1C)
Temperature Range:
-300 to 2000F
-184 to 1093C
Temp. Accuracy:
1.8F
1.0C
SD Memory Card:
Yes
Power:
120V Adapter
Accessories:
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
R157 AC Adapter
SW400 Logger Calibration Software
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
A202 K-Thermocouple 100' Straight Extension Cable
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
A870 7' Network Cable (category 5 ethernet cable)
A871 25' Network Cable (category 5 ethernet cable)
R007 9V Battery
R065 Universal International AC Adapter
A029 DicksonWare™ SECURE Software with Email Notification and
USB Download Cable (21CFR11 compliant) For use with Models SM720, SM725
and TM725
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SM725 Ethernet-Connect Temperature Data Logger With 2 Probes
Manage all data loggers in your network from one PC - connecting data
loggers to your Ethernet network is as easy as installing a printer!
Time-saving Data Management features-
• 24/7 feedback through Min/Max or Real-Time Display
• Visual/Audio alarms
• Optional Email alerts
• Remote access via Internet
• 2 K-thermocouple probes
Remote Temperature Range:
Full Range using A203 K-Thermocouple Probe: -300 to +2000°F (-184
to +1093°C)
Range with standard K-Thermocouple Probe: -300 to +500°F (-184 to
+260°C)
Remote Sensor:
4’ Teflon coated K-Thermocopule bead-wire probe with mini-connector
Remote Temperature Accuracy:
±1.8°F (±1°C) logger only
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95% RH non -condensing
Download Type:
USB, Serial or Standard Ethernet
Download Time:
1-Minute (USB); 3-Minutes (Serial); 2.0 Minutes (Ethernet)
Keypad Functions:
3 buttons with tactile feedback; Min/Max, Alarm, Save
Response Time:
1 minute to 63% of full scale, typical
Display:
Medium
Display Update Rate:
10 Seconds under battery power; 1 second under AC power.
Display Dimensions:
2.0" x 1.375"
Display Min/Max:
Yes
Resolution:
0.1° From 0.0 to 999.9; 1° over 1000
Power Source:
Battery (included/backup only), 1 9V; AC adapter (included)- (Input
Voltage/Current: 120VAC/60Hz/16W; Output Voltage/Current: 9VDC/1A; Optional
Universal International Adapter available
Power Status Indicator:
LCD Display
Input Connections:
Plugs directly into outlet; Output Connection: 3.5mm stereo plug; Length:
6 feet)
Battery Life (Avg):
3 Hours
Battery Backup:
Yes with AC Adapter
Memory:
EEPROM
Data Capacity:
32000
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 or
10 second increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Alarm:
Audio/Visual
Approvals:
CE
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point, Factory: NIST traceable
User Calibration w/ SW400:
Yes
Enclosure:
Polycarbonate
Mounting:
Wall mountable via keyhole slots
Included Accessories:
Battery, instruction manual, AC adapter - (Input Voltage/Current: 120VAC/60Hz/16W;
Output Voltage/Current: 9VDC/1A
DicksonWare™ Software Minimum Version Required:
9.0 DicksonWare Secure Software Required
DicksonWare™ PC/Software Requirements:
Windows® 98, 2000, and XP; PC with 486 MHz or better microprocessor,
16MB RAM, 1 free COM (serial) port with dedicated interrupt or 1 USB
root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
A025: 9 pin female D-shell to male 2.5mm stereo plug, 6 feet; A026:
USB male series “A” plug to 5-pin male series “B”
mini plug, 6’ (2 meters)
DicksonWare™ Computer Interface:
RS-232 serial (COM) port or USB
Units / Pkg:
1
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.High/Low Alarm
2.Min/Max Display
3.High Speed USB Connectivity
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Midsize Display Data
Logger, Midsize Display Logger, USB Logger, Dickson Data Logger, Dickson
Display Logger, Dickson SM, Datalogger, Temperature Data Logger, Memory
Card, Alarm, Digital Display Logger, Temperature Logger, Data Environment
Logger, Flash Memory Card, Alarm, K-Thermocouple Data Logger, K-TC Data
Logger, Remote Probe Data Logger, Remote Probe Logger, Thermocouple
Data Logger, High Temperature Data Logger, Two Channel Data Logger,
Datalogger, Ethernet Data Logger, Network Data Logger, Network Temperature
Data Logger, Ethernet Data Logger
Remote Probe:
Yes(2)
Remote Sensing Range:
-300 to +2000°F (w/A203 probe)
Temperature Accuracy:
±1.8F (±1C)
Network Connectivity:
Ethernet
Temperature Range:
-300 to 2000F
-184 to 1093C
Temp. Accuracy:
1.8F
1.0C
SD Memory Card:
Yes
Power:
120V Adapter
Accessories:
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
R007 9V Battery
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A060 Serial Download Cable Only
A061 USB Download Cable Only - 6FT
R157 AC Adapter
SW400 Logger Calibration Software
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
A202 K-Thermocouple 100' Straight Extension Cable
A870 7' Network Cable (category 5 ethernet cable)
A871 25' Network Cable (category 5 ethernet cable)
R065 Universal International AC Adapter
A029 DicksonWare™ SECURE Software with Email Notification and
USB Download Cable (21CFR11 compliant) For
use with
Models SM720, SM725 and TM725
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
FT300 Graph-at-a-Glance Temperature Data Logger
Digital Graph Visualizes Trends - this graphing data logger is the paperless
chart recorder of choice.
Full Featured Convenience-
• Jumbo 4.5” x 3.4” screen
• User-defined display settings
• 32KB storage
• Audio/Visual alarms
User Selectable Temperature Ranges:
0 to +100F, -10 to +40C, 0 to +50F
Temperature Range:
0 to 100F
-10 to 40C
0 to 50F
Temperature Accuracy:
±1.2F (±0.7C)
Temperature Sensor:
Thermistor
Sample Storage Rate:
Time graph interval options: 10 sec; 20 sec, 30 sec, 40 sec, 1 min,
2 min, 3 min (user selectable)
Time Samples Displayed:
Sample Rate/Time: 10 sec/45.8 min; 20 sec/1.5 hrs; 30 sec/2.3 hrs; 40
sec/3 hrs, 1 min/4.5hrs; 2 min/9.1 hrs; 3 min/13.7 hrs
Download Type:
USB (1:15 minutes) or FLASH Memory Card (36 seconds)
Alarm Type:
Audio/visual; High/low and low battery conditions
Ambient Operating Conditions:
Logger: 0 to 122F (-17.8 to 50C), 0 to 95% RH (non-condensing, dependent
upon display operating range)
Data Capacity:
32,000; 275 Sample Points Displayed on Graph
Power Source:
120 VAC / 60 Hz / 16 W adapter (9V battery back-up)
Power Status Indicator:
LCD Display
Power Cord:
6’ (2 meters)
Battery Backup:
Yes
Battery Life (Avg):
48-hours (when on battery power display goes to sleep after 1-minute
- can be reactivated with the push of any button)
Display:
LCD
4.5" x 3.4"
Display Update Rate:
Data: varies with logging interval
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
Factory: NIST traceable
User Calibration w/ SW400:
Yes
Approvals:
CE
Software Required:
None Required, A016 or A026 optional
Units / Pkg:
1
Dimensions (Inches/cm):
7.7"x 6"x 2.2" (19.6cm x 15.3cm x 5.5cm)
Weight:
21.34oz (605g)
IP Rating:
IP20
Mounting:
Wall and Keyhole
Response Time:
1 min to 63% FS typical
Warranty:
12-Month Limited
Storage Conditions:
-22 to 158F (-30 to 70C); 0 to 95% RH non-condensing
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, FlatScreen Data Logger,
Flat Panel LCD Logger, Graphical Display Data Logger, Dickson Data Logger,
Dickson Display Logger, Dickson FT, Temperature Logger, K-Thermocouple
Data Logger, K-TC Data Logger, Remote Probe Data Logger, Remote Probe
Logger, Thermocouple Data Logger, High Temperature Data Logger, Two
Channel Data Logger, Temperature Loggers, Data Environment Logger, Datalogger
Key Features:
1.Large 4.5" x 3.4" graphical display
2.No software or paper charts required
Temp. Accuracy:
±1.2F (±0.7C)
Alarm:
Yes
Accessories:
SW400 Logger Calibration Software
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
A210 Removeable FLASH Storage Device
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
R007 9V Battery
R157 AC Adapter
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
FT325 Graph-at-a-Glance Remote Probe Temperature Data Logger
Digital Graph Visualizes Trends - this graphing data logger is the paperless
chart recorder of choice.
Full Featured Convenience-
• Jumbo 4.5” x 3.4” screen
• Probe
• User-defined display settings
• 32KB storage
• Audio/Visual alarms
User Selectable Temperature Ranges:
-20 to +80F/C, -40 to +140F/C, 0 to +100F/C, 0 to +150F/C, 0 to +250F,
0 to +300F
Temperature Range:
-20 to 80F/C
-40 to 140F/C
0 to 100F/C
0 to 150F/C
0 to 250F
0 to 300F
Remote Temperature Range:
-40 to +300F
Temperature Accuracy:
±1.2F
(±0.7C)
Remote Temperature Accuracy:
±1.2F
(±0.7C)
Temperature Sensor:
Thermistor
Remote Sensor:
Thermistor with coated tip practical for immersion. 10ft. long.
Sample Storage Rate:
Time graph interval options: 10 sec; 20 sec, 30 sec, 40 sec, 1 min,
2 min, 3 min (user selectable)
Time Samples Displayed:
Sample Rate/Time: 10 sec/45.8 min; 20 sec/1.5 hrs; 30 sec/2.3 hrs; 40
sec/3 hrs, 1 min/4.5hrs; 2 min/9.1 hrs; 3 min/13.7 hrs
Download Type:
USB (1:15 minutes) or FLASH Memory Card (36 seconds)
Alarm Type:
Audio/visual; High/low and low battery conditions
Ambient Operating Conditions:
Logger: 0 to 120F (-17.8 to 49C), 0 to 95% RH (non-condensing, dependent
upon display operating range); Probe: -40 to +300°F (-40 to +150°C),
0 to 95% RH (non-condensing)
Data Capacity:
32,000 (16,000 per channel)
275 Sample Points Displayed on Graph
Power Source:
120 VAC / 60 Hz / 16 W adapter (9V battery back-up)
Power Status Indicator:
LCD Display
Power Cord:
6’ (2 meters)
Battery Backup:
Yes
Battery Life (Avg):
48-hours (when on battery power display goes to sleep after 1-minute
- can be reactivated with the push of any button)
Display:
LCD
4.5" x 3.4"
Display Update Rate:
Data: varies with logging interval
Remote Probe Dimensions:
10ft. long
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
Factory: NIST traceable
User Calibration w/ SW400:
Yes
Approvals:
CE
Software Required:
None Required, A016 or A026 optional
Units / Pkg:
1
Dimensions (Inches/cm):
7.7"x 6"x 2.2" (19.6cm x 15.3cm x 5.5cm)
Weight:
21.34oz (605g)
IP Rating:
IP20
Mounting:
Wall and Keyhole
Response Time:
1 min to 63% FS typical
Warranty:
12-Month Limited
Storage Conditions:
-22 to 158F (-30 to 70C); 0 to 95% RH non-condensing
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, FlatScreen Data Logger,
Flat Panel LCD Logger, Graphical Display Data Logger, Dickson Data Logger,
Dickson Display Logger, Dickson FT, Temperature Logger, K-Thermocouple
Data Logger, K-TC Data Logger, Remote Probe Data Logger, Remote Probe
Logger, Thermocouple Data Logger, High Temperature Data Logger, Two
Channel Data Logger, Temperature Loggers, Data Environment Logger, Datalogger
Key Features:
1.Remote probe
2.Large 4.5" x 3.4" graphical display
3.No software or paper charts required
Temp. Accuracy:
±1.2F
(±0.7C)
Alarm:
Yes
Remote Probe:
Yes
Accessories:
SW400 Logger Calibration Software
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
A210 Removeable FLASH Storage Device
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
R007 9V Battery
R157 AC Adapter
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
FT420 Graph-at-a-Glance HIGH ACCURACY(±.5F)Temperature Data Logger
Digital Graph Visualizes Trends - this highly accurate graphing data logger
is the paperless chart recorder of choice.
Full Featured Convenience-
• ±.5F Accuracy
• Jumbo 4.5” x 3.4” screen
• User-defined display settings
• 32KB storage
• Audio/Visual alarms
• 10ft. Thermistor Probe
User Selectable Temperature Ranges:
For ±.5F (±0.3C) accuracy: -20 to +80F/C, 0 to +100F,
0 to +150F,
For ±1.2F (±0.7C) accuracy: -40 to +140F/C, 0 to +100C,
0 to +150C, 0 to +250F, 0 to +300F
Remote Temperature Range:
-40 to 300F
Remote Temperature Accuracy:
±.5F(±0.3C)
from -20 to 176F (-28 to 80C)
±1.2F (±0.7C)
<-20F (-28C) and >176F (80C)
Remote Sensor:
Thermistor with coated tip practical for immersion. 10ft. long.
Sample Storage Rate:
Time graph interval options: 10 sec; 20 sec, 30 sec, 40 sec, 1 min,
2 min, 3 min (user selectable)
Time Samples Displayed:
Sample Rate/Time: 10 sec/45.8 min; 20 sec/1.5 hrs; 30 sec/2.3 hrs; 40
sec/3 hrs, 1 min/4.5hrs; 2 min/9.1 hrs; 3 min/13.7 hrs
Download Type:
USB (1:15 minutes) or FLASH Memory Card (36 seconds)
Alarm Type:
Audio/visual; High/low and low battery conditions
Ambient Operating Conditions:
Logger: 0 to 120F (-17.8 to 49C), 0 to 95% RH (non-condensing, dependent
upon display operating range); Probe: -40 to +300°F (-40 to +150°C),
0 to 95% RH (non-condensing)
Data Capacity:
32,000 (16,000 per channel)
275 Sample Points Displayed on Graph
Power Source:
120 VAC / 60 Hz / 16 W adapter (9V battery back-up)
Power Status Indicator:
LCD Display
Power Cord:
6’ (2 meters)
Battery Backup:
Yes
Battery Life (Avg):
48-hours (when on battery power display goes to sleep after 1-minute
- can be reactivated with the push of any button)
Display:
LCD
4.5" x 3.4"
Display Update Rate:
Data: varies with logging interval
Remote Probe Dimensions:
10ft. long
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
Factory: NIST traceable
User Calibration w/ SW400:
Yes
Approvals:
CE
Software Required:
None Required, A016 or A026 optional
DicksonWare™ Software Minimum Version Required:
12.4
Units / Pkg:
1
Dimensions (Inches/cm):
7.7"x 6"x 2.2" (19.6cm x 15.3cm x 5.5cm)
Weight:
21.34oz (605g)
IP Rating:
IP20
Mounting:
Wall and Keyhole
Response Time:
1 min to 63% FS typical
Warranty:
12-Month Limited
Storage Conditions:
-22 to 158F (-30 to 70C); 0 to 95% RH non-condensing
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, FlatScreen Data Logger,
Flat Panel LCD Logger, Graphical Display Data Logger, Dickson Data Logger,
Dickson Display Logger, Dickson FT, Temperature Logger, K-Thermocouple
Data Logger, K-TC Data Logger, Remote Probe Data Logger, Remote Probe
Logger, Thermocouple Data Logger, High Temperature Data Logger, Two
Channel Data Logger, Temperature Loggers, Data Environment Logger, Datalogger
Key Features:
1.Remote probe
2.Large 4.5" x 3.4" graphical display
3.No software or paper charts required
Temp. Accuracy:
±.5F
(±0.3C)
Alarm:
Yes
Remote Probe:
Yes
Temperature Range:
-20 to 80F/C
0 to 100F
0 to 150F
Accessories:
SW400 Logger Calibration Software
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
A210 Removeable FLASH Storage Device
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
R007 9V Battery
R157 AC Adapter
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
HT200 NEW Takes-the-Heat-Watertight, High-Temp Temperature Data Logger
Place in Wet or Dry-- Put this data logger exactly where you need to—in
incubators, food processing equipment, chemical storage tanks, wherever…
Built to take the heat--
• HACCP and FDA-compliant
• Food grade stainless steel case
• Temperature resistant up to 257F
• User Replaceable 1-year battery
• High Speed USB Data Download
Temperature Range:
-40 to 257F
-40 to 125C
Temperature Accuracy:
±1.8F (±1C) over entire range
Temperature Sensor:
Thermistor
Ambient Operating Conditions:
-40 to 257F (-40 to 125C)
Data Capacity:
32,512
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
High Energy Lithium Battery (Tadiran)- User Replaceable
Battery Life (Avg):
1-year at 1-minute sample rate (ambient conditions)
Download Time:
Approximately 1 Minute, typical when not logging
Response Time:
15 minutes to move 63% of full scale
Resolution:
0.1F
0.1C
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: zero point & span NIST traceable
User Calibration w/ SW400:
Yes
Approvals:
CE
Enclosure:
316 food grade stainless steel
Software Required:
A016 or A026
DicksonWare™ Software Minimum Version Required:
15.5
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or better
DicksonWare™ Cable Type/Length:
USB Male Series A plug to 5 pin male series B mini plug - 6 feet
DicksonWare™ Computer Interface:
USB
Units / Pkg:
1
Dimensions (Inches/cm):
5.36" x 0.75" DIA; 13.6cm x 1.9cm DIA
Weight:
5.2 oz
148g
IP Rating:
IP68
Warranty:
12-Month Limited
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Dickson HT, Dickson
High Temperature Logger, Dickson High Temperature Data Logger, Data
Logger, Logger, Temperature Data Logger, Data Environment Logger, Waterproof
Data Logger, Stainless Steel Data Logger, Bottle Logger, Process Logger,
Process Data Logger, Temperature Logger, Datalogger
Temp. Accuracy:
1.8F
1.0C
Stainless Steel:
Yes
Waterproof:
Yes
Power:
Battery
Accessories:
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
SW400 Logger Calibration Software
SW701 DicksonWare™ Upgrade
R170 Tadiran Battery TL-5955 (#103019)
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
HT220 NEW Takes-the-Heat-Watertight, Piercing Probe Temperature Data Logger
HACCP and FDA-Compliant--Food grade stainless steel case perfect for food,
beverage, and agricultural products.
Place in HOT, WET, or DRY--Put this data logger exactly where you need
to!
• Reinforced piercing probe
• Temperature resistant up to 257F
• User Replaceable 1-year battery
• High Speed USB Data Download
Temperature Range:
-40 to 257F
-40 to 125C
Temperature Accuracy:
±1.8F (±1C) over entire range
Temperature Sensor:
Thermistor
Ambient Operating Conditions:
-40 to 257F (-40 to 125C)
Data Capacity:
32,512
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
High Energy Lithium Battery (Tadiran)- User Replaceable
Battery Life (Avg):
1-year at 1-minute sample rate (ambient conditions)
Download Time:
Approximately 1 Minute, typical when not logging
Response Time:
Less than 1 minute to move 63% of full scale
Resolution:
0.1F
0.1C
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: zero point & span NIST traceable
User Calibration w/ SW400:
Yes
Approvals:
CE
Enclosure:
316 food grade stainless steel
Software Required:
A016 or A026
DicksonWare™ Software Minimum Version Required:
15.5
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or better
DicksonWare™ Cable Type/Length:
USB Male Series A plug to 5 pin male series B mini plug - 6 feet
DicksonWare™ Computer Interface:
USB
Units / Pkg:
1
Dimensions (Inches/cm):
5.36" x 0.75" DIA; 13.6cm x 1.9cm DIA (Case only)
Weight:
5.4 oz
154g
IP Rating:
IP68
Warranty:
12-Month Limited
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Dickson HT, Dickson
High Temperature Logger, Dickson High Temperature Data Logger, Data
Logger, Logger, Temperature Data Logger, Data Environment Logger, Waterproof
Data Logger, Stainless Steel Data Logger, Bottle Logger, Process Logger,
Process Data Logger, Temperature Logger, Datalogger
Piercing Probe:
2.36" x 0.19" DIA
Temp. Accuracy:
1.8F
1.0C
Stainless Steel:
Yes
Waterproof:
Yes
Power:
Battery
Accessories:
DicksonWare™ SECURE Software and USB Download Cable (21CFR11 compliant)
A016 DicksonWare™ Software USB Download Cable
SW400 Logger Calibration Software
SW701 DicksonWare™ Upgrade
R170 Tadiran Battery TL-5955 (#103019)
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
HT225 NEW Takes-the-Heat-Watertight, Piercing Probe Temperature Data Logger
HACCP and FDA-Compliant--Food grade stainless steel case perfect for food,
beverage, and agricultural products.
Place in HOT, WET, or DRY--Put this data logger exactly where you need
to!
• Reinforced piercing probe
• Temperature resistant up to 257F
• User Replaceable 1-year battery
• High Speed USB Data Download
Temperature Range:
-40 to 257F
-40 to 125C
Temperature Accuracy:
±1.8F (±1C) over entire range
Temperature Sensor:
Thermistor
Ambient Operating Conditions:
-40 to 257F (-40 to 125C)
Data Capacity:
32,512
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
High Energy Lithium Battery (Tadiran)- User Replaceable
Battery Life (Avg):
1-year at 1-minute sample rate (ambient conditions)
Download Time:
Approximately 1 Minute, typical when not logging
Response Time:
Less than 1 minute to move 63% of full scale
Resolution:
0.1F
0.1C
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: zero point & span NIST traceable
User Calibration w/ SW400:
Yes
Approvals:
CE
Enclosure:
316 food grade stainless steel
Software Required:
A016 or A026
DicksonWare™ Software Minimum Version Required:
15.5
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or better
DicksonWare™ Cable Type/Length:
USB Male Series A plug to 5 pin male series B mini plug - 6 feet
DicksonWare™ Computer Interface:
USB
Units / Pkg:
1
Dimensions (Inches/cm):
5.36" x 0.75" DIA; 13.6cm x 1.9cm DIA (Case only)
Weight:
5.4 oz
153g
IP Rating:
IP68
Warranty:
12-Month Limited
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Dickson HT, Dickson
High Temperature Logger, Dickson High Temperature Data Logger, Data
Logger, Logger, Temperature Data Logger, Data Environment Logger, Waterproof
Data Logger, Stainless Steel Data Logger, Bottle Logger, Process Logger,
Process Data Logger, Temperature Logger, Datalogger
Piercing Probe:
4.88" x 0.11" DIA
Temp. Accuracy:
1.8F
1.0C
Stainless Steel:
Yes
Waterproof:
Yes
Power:
Battery
Accessories:
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
SW400 Logger Calibration Software
SW701 DicksonWare™ Upgrade
R170 Tadiran Battery TL-5955 (#103019)
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SP325 Multi-feature Digital Display Temperature Data Logger
Digital Display Makes it Easy! -- lets you keep track of temperature conditions
in between data downloads.
Added User-friendly features-
• Push-to-Start Recording
• Display current temp and/or min/max readings
• User-replaceable battery
• USB-enabled triple-speed data downloading
Temperature Range:
-4 to 158F
-20 to 70C
Temperature Accuracy:
±1.2F (±0.7C)
Temperature Sensor:
Internal digital temperature sensor
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95%RH (non-condensing)
Display:
Small
Display Min/Max:
Yes
Display Update Rate:
Every 20 Seconds
Display Resolution:
Display: 1°F (1°C)
Data Capacity:
32512
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
123A Lithium; user replaceable
Power Status Indicator:
LED flashes green when sampling
Battery Life (Avg):
1-year
Resolution:
Logger: 0.1°F (0.1°C)
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: NIST traceable
User Calibration w/ SW400:
Yes
DicksonWare™ Software Minimum Version Required:
11
Software Required:
A016
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or higher; PC w/ 486 MHz or faster microprocessor,
16 MB RAM, 1 free USB root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
USB male series "A" plug to 5-pin male series "B"
mini plug, 6 ft (2 meters)
DicksonWare™ Computer Interface:
USB
Software Features:
Selectable Sample Interval, F/C Selectable, Wrap or Stop when Full,
Delayed Start, Real Time Monitoring and Much More.
Download Time:
1-minute when logger is full
Dimensions (Inches/cm):
1.34x3.08x2.25
3.4x7.8x5.7
Weight:
4 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.One Year - User Replaceable Battery
2.Push-to-Start
3.Display
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Pro Series Data Logger,
Pro Logger, Pro Data Logger, Dickson Data Logger, Dickson Logger, Dickson
SP, Datalogger, Temperature Data Logger, Temperature Logger, Data Environment
Logger, K-Thermocouple Data Logger, High Temperature Data Logger, Datalogger,
Push-to-Start, Display
Download Type:
USB
Temp. Accuracy:
1.2F
0.67C
Push to Start:
Yes
Digital Display:
Yes
Network Connectivity:
MP100
Power:
Battery
Accessories:
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A715 Locking Wall Mount Case, Small
A713 Water-resistant Pouch, Soft, Small
SW400 Logger Calibration Software
A061 USB Download Cable Only - 6FT
A125 3V Lithium 123A
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SP425 Start & Stop, Digital Display, Temperature Data Logger
Record only the data you want to!
Our new Start & Stop feature allows you to quickly start or stop
logging at any time allowing you to eliminate unnecessary data.
Start and Stop multiple times before downloading to DicksonWare.
Each logging session is easily identified on the graph and table.
Digital Display Makes it Easy! -- lets you keep track of temperature
conditions in between data downloads.
Added User-friendly features-
• Start/Stop Recording: Lets you Start and Stop logging repeatedly
without having to take the logger back to your PC.
• Display current temp or current/min/max readings
• User-replaceable battery
• USB-enabled triple-speed data downloading
Temperature Range:
-4 to 158F
-20 to 70C
Temperature Accuracy:
±1.2F (±0.7C)
Temperature Sensor:
Internal digital temperature sensor
Ambient Operating Conditions:
-4 to 158F (-20 to 70C); 0 to 95%RH (non-condensing)
Display:
Small
Display Indicators:
Display Solid or Scrolling while logging
Display Flashes when unit is full or in Delayed Start mode.
Display is blank when logger is off waiting for Push to Start.
Display Min/Max:
Yes
Display Update Rate:
Every 20 Seconds
Display Resolution:
Display: 1°F (1°C)
Data Capacity:
32512
16-bit Samples
Sample Interval:
Records data in configurable 1 second to 24 hour intervals, in 1 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
123A Lithium; user replaceable
Battery Life (Avg):
1-year
Resolution:
Logger: 0.1°F (0.1°C)
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: NIST traceable
User Calibration w/ SW400:
Yes
DicksonWare™ Software Minimum Version Required:
13.6
Software Required:
A016
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 98 or higher; PC w/ 486 MHz or faster microprocessor,
16 MB RAM, 1 free USB root hub, CD drive, VGA monitor or better
DicksonWare™ Cable Type/Length:
USB male series "A" plug to 5-pin male series "B"
mini plug, 6 ft (2 meters)
DicksonWare™ Computer Interface:
USB
Software Features:
Selectable Sample Interval, F/C Selectable, Wrap or Stop when Full,
Delayed Start, Real Time Monitoring and Much More.
Download Time:
1-minute when logger is full
Dimensions (Inches/cm):
1.34x3.08x2.25
3.4x7.8x5.7
Weight:
4 oz
IP Rating:
IP20
Warranty:
12-Month Limited
Key Features:
1.One Year - User Replaceable Battery
2.Push-to-Start
3.Display
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Pro Series Data Logger,
Pro Logger, Pro Data Logger, Dickson Data Logger, Dickson Logger, Dickson
SP, Datalogger, Temperature Data Logger, Temperature Logger, Data Environment
Logger, K-Thermocouple Data Logger, High Temperature Data Logger, Datalogger,
Push-to-Start, Display
Download Type:
USB
Temp. Accuracy:
1.2F
0.67C
Digital Display:
Yes
Power:
Battery
Start/Stop:
Yes
Accessories:
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A715 Locking Wall Mount Case, Small
A713 Water-resistant Pouch, Soft, Small
SW400 Logger Calibration Software
A061 USB Download Cable Only - 6FT
A125 3V Lithium 123A
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
WFC320 Vaccine Temperature Data Logger
Saves $$$ in ways min/max thermometers cannot-- CDC-recommended continuous
data recorders tell you how long vaccine temps were out of range.
Geared for Fast-paced Clinical Settings--
• K-Thermocouple Probe
• Glycol bottle stability for open/shut refrigerator doors
• Jumbo display with min/max option and visual/audio alarms
• USB-enabled triple speed downloading
• FLASH memory card data transfer-capable
Temperature Range:
Internal:
-4 to 158F
-20 to 70C
External:
-20 to 158F
-29 to 70C
Temperature Accuracy:
±1.8%
Temperature Sensor:
External: 4 ft Teflon coated K-Thermocouple beadwire probe with mini-connector,
Internal: Thermistor
Ambient Operating Conditions:
-4 to +158°F (-20 to +70°C), 0 to 95% RH (non-condensing)(logger
only)
Power Source:
4 AA alkaline batteries (user replaceable) and AC adapter (input voltage/current:
120VAC/60Hz/16W; output voltage/current: 9VDC/1A)
Battery Life (Avg):
6-months
Display:
Medium
Display Dimensions:
2.0" x 1.375"
Response Time:
1 minute to move 63% of full scale, typical - dependent on K-type probe
used
Resolution:
0.1F from 0.0 to 999.9; 1° over 1000
Approvals:
CE
Enclosure:
Polycarbonate
Calibration:
User: zero point; Factory: zero and span
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
Included Accessories:
Batteries, instruction manual, AC adapter with 10 ft cable, velcro mounting
strip, standard certificate of calibration, K-Type Thermocouple beadwire
probe, propelyne glycol bottle w/septum closure
Warranty:
12-Month Limited
Keypad Functions:
3 buttons with tactil feedback; min/max, alarm, save
Input Connections:
Plugs directly into outlet; Output connection: 3.5 mm phone plug 6 ft
in length
Sample Interval:
1 sample per channel every 5 minutes
Memory:
Type: EEPROM, removable flash storage device
Alarm Type:
High/low audible alarm; visual "ALRN" on display
Mounting:
Wall mountable via keyhole slots
Storage Conditions:
-40 to +176°F (-40 to +80°C); 0 to 100% RH non-condensing (logger
only)
Alarm Delay:
Option to eliminate false alarms from cycling and door openings
Glycol Solution:
Propelyneglycol bottle
Data Capacity:
32000
16-bit Samples
A.K.A.:
Dickson VFC, Dickson Vaccines for Children Recorder, Vaccines for Children
Data Logger, Vaccine Data Logger, Vaccine Monitor, Dickson SM, Dickson
TempTrace, Dickson Temptrace, Dickson Temperature Data Logger, Temperature
Logger, Data Logger, Display Logger, LCD Display, Digital Display, adsorbed
rabies vaccine, adverse reaction vaccine, aids vaccine, alzheimers vaccine,
anthrax vaccine, anthrax vaccine side effects, b conjugate haemophilus
vaccine, b haemophilus influenzae type vaccine, bcg vaccine, bordetella
vaccine, cancer vaccine, cat vaccine, center information national vaccine,
chicken pox reaction vaccine, chicken pox vaccine, child immunization,
child vaccine, child vaccines, cholera vaccine, company vaccine, conjugate
pneumococcal vaccine, contemporary vaccine issue, dog rabies vaccine,
dog schedule vaccine, dog vaccine, dpt vaccine, dtap vaccine, dtp vaccine,
edible vaccine, equine nile vaccine west, flu vaccine, flu vaccine storage,
freezer used for vaccine storage, guidelines for vaccine cold chain,
haemophilus b polysaccharide vaccine, handling storage vaccine, havrix
vaccine, hep b vaccine, hepatitis b vaccine, hepatitis b vaccine side
effects, hepatitis c vaccine, herpes vaccine, hib vaccine, hiv vaccine,
horse nile vaccine virus west, horse nile vaccine west, hpv vaccine,
immunization record, immunization vaccine, imovax rabies vaccine, influenza
vaccine, influenza virus vaccine, information sheet vaccine, information
statement vaccine, is hb vaccine, japanese encephalitis virus vaccine,
je vaccine vax, lyme disease vaccine, lyme vaccine, maintaining vaccine
cold chain, malaria vaccine, managing the vaccine cold chain, measles
mumps and rubella vaccine, measels vaccine, measles virus vaccine, melanoma
vaccine, meningitis vaccine side effects, meningococcal vaccine, military
vaccine education center, mmr vaccine, mmr vaccine side effects, monitor
vaccine storage temperature, mumps vaccine, mumps virus vaccine, mumps
virus vaccine live, nile vaccine virus west, niles vaccine west, omaha
vaccine, omaha vaccine company, pertusis vaccine, pet vaccine, pnemococcal
vaccine, pneumonia vaccine, polio vaccine, power outage vaccine, power
outage vaccine storage, preventing vaccine, prevnar vaccine, proper
vaccine storage, rabavert rabies vaccine, rabies vaccine, rabies vaccine
human diploid cell, rubella vaccine, rubella virus vaccine, sabin vaccine,
safe handling of vaccines, safe vaccine handling, salk vaccinee, schedule
vaccine, shop vaccine, small pox vaccine, temperature monitor for vaccines,
tetanus vaccine, tuberculosis vaccine, twinrix vaccine, typhoid vaccine,
vaccine accountability, vaccine awareness, vaccine awareness coalition,
vaccine chart recorder, vaccine cold chain, vaccine cold store, vaccine
efficacy, vaccine freezer, vaccine handling, vaccine information, vaccine
issue, vaccine issue and concern, vaccine logger, vaccine lung cancer,
vaccine management, vaccine potency, vaccine reaction, vaccine refrigerator,
vaccine risk awareness, vaccine safe storage, vaccine safery and efficacy
issue, vaccine safety issue, vaccine stock efficacy, vaccine storage,
vaccine storage and viability, vaccine storage guidelines, vaccine storage
procedure, vaccine storage recommendation, vaccine storage requirement,
vaccine storage temps, vaccine storage unit, vaccine supply, vaccine
temp recorder, vaccine temperature, vaccine temperature log, vaccine
thermometer, vaccine thimerosal, vaccine varicella virus, vaccine vax
yf, vaccine vial monitor, varicella vaccine, varicella virus vaccine
live, whooping cough vaccine, yellow fever vaccine
Power:
Battery
Temp. Accuracy:
1.8F
1C
Display Min/Max:
Yes
Alarm:
Audio/Visual
Remote Probe:
Yes
SD Memory Card:
Yes
Accessories:
A210 Removeable FLASH Storage Device
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ Software Serial Download Cable
R006 "AA" Alkaline battery
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
SW400 Logger Calibration Software
A061 USB Download Cable Only - 6FT
A340 Bottle of Propelyne Glycol Solution
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
R157 AC Adapter
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
WFC325 Vaccine Double Probe Temperature Data Logger
Saves $$$ in ways min/max thermometers cannot-- CDC-recommended continuous
data recorders tell you how long vaccine temps were out of range.
Geared for Fast-paced Clinical Settings--
• 2 K-Thermocouple Probe
• Glycol bottle stability for open/shut refrigerator doors
• Jumbo display with min/max option and visual/audio alarms
• USB-enabled triple speed downloading
• FLASH memory card data transfer-capable
Temperature Range:
Internal:
-4 to 158F
-20 to 70C
External:
-20 to 158F
-29 to 70C
Temperature Accuracy:
±1.8%
Temperature Sensor:
External: two 4 ft Teflon coated K-Thermocouple beadwire probes with
mini-connector
Ambient Operating Conditions:
-4 to +158°F (-20 to +70°C), 0 to 95% RH (non-condensing)(logger
only)
Power Source:
4 AA alkaline batteries (user replaceable) and AC adapter (input voltage/current:
120VAC/60Hz/16W; output voltage/current: 9VDC/1A)
Battery Life (Avg):
6-months
Display:
Medium
Display Dimensions:
2.0" x 1.375"
Response Time:
1 minute to move 63% of full scale, typical - dependent on K-type probe
used
Resolution:
0.1F from 0.0 to 999.9; 1° over 1000
Approvals:
CE
Enclosure:
Polycarbonate
Calibration:
User: zero point; Factory: zero and span
Dimensions (Inches/cm):
4.0x3.0x1.6
10.2x7.7x3.9
Weight:
9 oz
Included Accessories:
Batteries, instruction manual, AC adapter with 10 ft cable, velcro mounting
strip, standard certificate of calibration, K-Type Thermocouple beadwire
probe, propelyne glycol bottle w/septum closure
Warranty:
12-Month Limited
Keypad Functions:
3 buttons with tactil feedback; min/max, alarm, save
Input Connections:
Plugs directly into outlet; Output connection: 3.5 mm phone plug 6 ft
in length
Sample Interval:
1 sample per channel every 5 minutes
Memory:
Type: EEPROM, removable flash storage device
Alarm Type:
High/low audible alarm; visual "ALRN" on display
Mounting:
Wall mountable via keyhole slots
Storage Conditions:
-40 to +176°F (-40 to +80°C); 0 to 100% RH non-condensing (logger
only)
Alarm Delay:
Option to eliminate false alarms from cycling and door openings
Glycol Solution:
Propelyneglycol
Data Capacity:
32000
16-bit Samples
A.K.A.:
Dickson VFC, Dickson Vaccines for Children Recorder, Vaccines for Children
Data Logger, Vaccine Data Logger, Vaccine Monitor, Dickson SM, Dickson
TempTrace, Dickson Temptrace, Dickson Temperature Data Logger, Temperature
Logger, Data Logger, Display Logger, LCD Display, Digital Display, adsorbed
rabies vaccine, adverse reaction vaccine, aids vaccine, alzheimers vaccine,
anthrax vaccine, anthrax vaccine side effects, b conjugate haemophilus
vaccine, b haemophilus influenzae type vaccine, bcg vaccine, bordetella
vaccine, cancer vaccine, cat vaccine, center information national vaccine,
chicken pox reaction vaccine, chicken pox vaccine, child immunization,
child vaccine, child vaccines, cholera vaccine, company vaccine, conjugate
pneumococcal vaccine, contemporary vaccine issue, dog rabies vaccine,
dog schedule vaccine, dog vaccine, dpt vaccine, dtap vaccine, dtp vaccine,
edible vaccine, equine nile vaccine west, flu vaccine, flu vaccine storage,
freezer used for vaccine storage, guidelines for vaccine cold chain,
haemophilus b polysaccharide vaccine, handling storage vaccine, havrix
vaccine, hep b vaccine, hepatitis b vaccine, hepatitis b vaccine side
effects, hepatitis c vaccine, herpes vaccine, hib vaccine, hiv vaccine,
horse nile vaccine virus west, horse nile vaccine west, hpv vaccine,
immunization record, immunization vaccine, imovax rabies vaccine, influenza
vaccine, influenza virus vaccine, information sheet vaccine, information
statement vaccine, is hb vaccine, japanese encephalitis virus vaccine,
je vaccine vax, lyme disease vaccine, lyme vaccine, maintaining vaccine
cold chain, malaria vaccine, managing the vaccine cold chain, measles
mumps and rubella vaccine, measels vaccine, measles virus vaccine, melanoma
vaccine, meningitis vaccine side effects, meningococcal vaccine, military
vaccine education center, mmr vaccine, mmr vaccine side effects, monitor
vaccine storage temperature, mumps vaccine, mumps virus vaccine, mumps
virus vaccine live, nile vaccine virus west, niles vaccine west, omaha
vaccine, omaha vaccine company, pertusis vaccine, pet vaccine, pnemococcal
vaccine, pneumonia vaccine, polio vaccine, power outage vaccine, power
outage vaccine storage, preventing vaccine, prevnar vaccine, proper
vaccine storage, rabavert rabies vaccine, rabies vaccine, rabies vaccine
human diploid cell, rubella vaccine, rubella virus vaccine, sabin vaccine,
safe handling of vaccines, safe vaccine handling, salk vaccinee, schedule
vaccine, shop vaccine, small pox vaccine, temperature monitor for vaccines,
tetanus vaccine, tuberculosis vaccine, twinrix vaccine, typhoid vaccine,
vaccine accountability, vaccine awareness, vaccine awareness coalition,
vaccine chart recorder, vaccine cold chain, vaccine cold store, vaccine
efficacy, vaccine freezer, vaccine handling, vaccine information, vaccine
issue, vaccine issue and concern, vaccine logger, vaccine lung cancer,
vaccine management, vaccine potency, vaccine reaction, vaccine refrigerator,
vaccine risk awareness, vaccine safe storage, vaccine safery and efficacy
issue, vaccine safety issue, vaccine stock efficacy, vaccine storage,
vaccine storage and viability, vaccine storage guidelines, vaccine storage
procedure, vaccine storage recommendation, vaccine storage requirement,
vaccine storage temps, vaccine storage unit, vaccine supply, vaccine
temp recorder, vaccine temperature, vaccine temperature log, vaccine
thermometer, vaccine thimerosal, vaccine varicella virus, vaccine vax
yf, vaccine vial monitor, varicella vaccine, varicella virus vaccine
live, whooping cough vaccine, yellow fever vaccine
Power:
Battery
Temp. Accuracy:
1.8F
1C
Display Min/Max:
Yes
Alarm:
Audio/Visual
Remote Probe:
Yes(2)
SD Memory Card:
Yes
Accessories:
A210 Removeable FLASH Storage Device
A061 USB Download Cable Only - 6FT
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
A025 DicksonWare™ SECURE Software and Serial Download Cable (21CFR11
compliant)
A016 DicksonWare™ Software USB Download Cable
A015 DicksonWare™ Software Serial Download Cable
R006 "AA" Alkaline battery
A220 Card Reader Kit - Includes USB Memory Card Reader and One Flash
Memory Card.
SW400 Logger Calibration Software
A340 Bottle of Propelyne Glycol Solution
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
R157 AC Adapter
R065 Universal International AC Adapter
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SX100 Self Contained Temperature Data Logger
The SX100 is a self-contained, low cost, single channel temperature Data
Logger. Great for HACCP, SPC, and Quality Control.
Temperature Range:
-40 to 176F
-40 to 80C
Temperature Accuracy:
±2.25F (+14 to +176F)
Temperature Sensor:
Digital sensor
Ambient Operating Conditions:
-40 to +176°F (-40 to +80°C), 0 to 95% RH (non-condensing)
Data Capacity:
7680
16-bit Samples
Sample Interval:
Records data in configurable 10 second to 24 hour intervals, in 10 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
3V lithium coin cell battery (user replaceable)
Battery Life (Avg):
1-year
Power Status Indicator:
LED Indicator
Resolution:
0.9F
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point, Factory: NIST traceable
Approvals:
CE
Software Required:
A015
DicksonWare™ Software Minimum Version Required:
6.0.0.5
DicksonWare™ Cable Type/Length:
9 pin male D-shell to male 2.5mm stereo plug, 6’ long
DicksonWare™ Computer Interface:
RS-232 COM (serial) port
Dimensions (Inches/cm):
3.1x2.1x0.9
7.9x5.4x2.2
IP Rating:
IP20
Weight:
1.8 oz
49g
Warranty:
12-Month Limited
A.K.A.:
Data Logger, Computers, Hardware, Test Equipment, Pro Series Data Logger,
Pro Logger, Pro Data Logger, Dickson Data Logger, Dickson Logger, Dickson
SX, Datalogger, Temperature Data Logger, Temperature Logger, Data Environment
Logger, Datalogger
Network Connectivity:
MP100
Temp. Accuracy:
2.25F
Accessories:
A015 DicksonWare™ Software Serial Download Cable
SW701 DicksonWare™ Upgrade
X025 25' (7.625m) Serial Extension Download Cable
X050 50' (15.25m) Serial Extension Download Cable
A060 Serial Download Cable Only
A170 Serial to USB Adapter
A715 Locking Wall Mount Case, Small
A713 Water-resistant Pouch, Soft, Small
A100 3 Volt Lithium Coin Cell Battery- CR2032
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
Dickson
SK550 12-Pack Bargain - Coin-sized Temperature Data Loggers
NOW WITH USB
When Price and Portability Matter Most- Buy loggers by the dozen for mapping
larger warehouses, recording temperature and humidity during shipping,
HVAC/R audits, and more.
The Compact Data Logger Choice--
• Lower per unit price
• Easy-to-use
• Unfailing Accuracy
Temperature Range:
-4 to 158F
-20 to 70C
Temperature Accuracy:
±1.8F (±1C) over range -4 to +158F (-20 to +70C)
Temperature Sensor:
Digital Sensor
Ambient Operating Conditions:
-4 to +158°F (-20 to +70°C), 0 to 95% RH (non-condensing)
Data Capacity:
7936
16-bit Samples
Sample Interval:
Records data in configurable 10 second to 24 hour intervals, in 10 second
increments.
Sample Storage Rate:
Storage rate until logger is full may vary, dependent upon selected
Sample Interval.
Power Source:
3V lithium battery (user replaceable)
Battery Life (Avg):
1-year
Memory:
EEPROM
Response Time:
10 minutes to 63% full scale
Download Time:
30-seconds, typical with logger full
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: none, Factory: NIST traceable
Software Required:
A016 or A026
DicksonWare™ Software Minimum Version Required:
15.5.0
DicksonWare™ PC/Software Requirements:
Microsoft Windows® 95, 98, 2000, NT or XP; PC w/ 386 MHz or faster
microprocessor, 4 MB RAM, 1 free COM (serial) port, CD drive
DicksonWare™ Cable Type/Length:
USB, 6’ long
DicksonWare™ Computer Interface:
USB
Approvals:
CE
Enclosure:
Polycarbonate
Units / Pkg:
12
Dimensions (Inches/cm):
1.75x1.4x0.62
4.4x3.5x1.6
Weight:
0.44 oz
12.4g
IP Rating:
IP20
Included Accessories:
Battery
Warranty:
12-Month Limited
Accuracy:
±1.8F
(±1C)
Key Features:
1.Less than $53 each
2.Slightly larger than a quarter
A.K.A.:
Computers, Hardware, Test Equipment, Dickson TK, Dickson Data Logger,
Dickson Logger, Datalogger, Temperature and Humidity Data Logger, Temperature
and Humidity Logger, Data Environment Logger, Transportation Logger,
Portable Logger, Datalogger
Temp. Accuracy:
1.8F
1.0C
Power:
Battery
Accessories:
A124 3V for USB Pro Series CR2450
SW701 DicksonWare™ Upgrade
A016 DicksonWare™ Software USB Download Cable
A026 DicksonWare™ SECURE Software and USB Download Cable (21CFR11
compliant)
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
N520 Certificate of Validation
Back to Top
|