Other Temperature Products
|
| Model # |
Resolution |
Temperature Range |
Remote Probe Dimensions |
|
0.1° between -19.9 to 199.9, otherwise 1° |
-58 to +302°F (-50 to +150°C) |
125 mm |
Dickson Digital Pen Thermometer
|
| Model # |
Response Time |
Temperature Range / Accuracy |
Memory |
|
20 seconds full scale |
-58 to +571°F (-50 to +300°C) |
Records MIN/MAX temperature |
| Dickson Min/Max Temperature Indicator
& Alarm |
| Model # |
Temperature Sensor |
Temperature Range |
Temperature Accuracy |
|
Thermistor hard wired to PCB, submersible tip
sealed in leak-proof glycol bottle |
-58 to +122°F (-50 to 50°C) |
±1.8 over 0 to 122°F and ±
3.6 deg <0°F |
|
Thermistor hard wired to PCB, submersible tip
sealed in leak-proof glycol bottle |
-58 to +122°F (-50 to 50°C) |
±1.8 over 0 to 120°F and ±
3.6 deg <0°F |
Dickson Temperature Indicator |
|
Model # |
Remote Sensor |
Remote Temperature Range |
Ambient Operating Conditions |
|
K, J, or T Thermocouple |
-300 to +1999°F (-184 to +1093°C) (using
optional A203 K-TC Probe)**-300 to +1650°F (-184 to +898°C)(using
standard K-TC Probe) |
+32 to +120°F (0 to +50°C), 0 to 95%
RH (non-condensing) |
Dickson
D115 Digital Thermometer
Spot check temperatures without fuss.
Robust and accurate thermometer for instant Temperature monitoring--
• Auto-off after 10 Minutes
• Convenient pen clip
• -58 to +302F range (-50 to +150C)
Temperature Range:
-58 to +302°F (-50 to +150°C)
Temperature Accuracy:
±2°F (±1°C) between -58 to +302°F (-50 to
200°C) otherwise, more then ±4°F (±2°C)
Power:
Battery: 1 pc x 1.5 volt type LR44 or equivalent
Remote Probe Dimensions:
125 mm
Sample Storage Rate:
1 second
Resolution:
0.1° between -19.9 to 199.9, otherwise 1°
A.K.A.:
Pen Thermometer, Temperature Indicator, Thermometer
Accessories:
A100 3 Volt Lithium Coin Cell Battery- CR2032
TC200 Spot-Check Handheld Temperature Indicator
Back to Top
Dickson
D154 Digital Thermometer
Spot check temperatures without fuss.
Robust and accurate thermometer for instant Temperature monitoring--
• Waterproof
• Auto-off after one hour
• Low battery indicator
• Convenient pen clip
• -58 to +571F range (-50 to +300C)
Temperature Range:
-58 to +571°F (-50 to +300°C)
Temperature Accuracy:
±2F for temperatures ranging -58 to +302F (-50 to +150C); ±4F
for temperatures ranging +302 to +392F (+150 to +200C); ±6F for
temperatures ranging +392 to +571F (+200 to +300C)
Resolution:
0.1°F to 199.9 and 1°F from 200 to 300; 0.1°C throughout
Celsius range
Response Time:
20 seconds full scale
Battery Life (Avg):
1-year
Memory:
Records MIN/MAX temperature
Scales:
Fahrenheit or Celsius switchable
Dimensions (Inches/cm):
5.75" in length, 3" probe
A.K.A.:
Pen Thermometer, Temperature Indicator, Thermometer
Accessories:
A100 3 Volt Lithium Coin Cell Battery- CR2032
Back to Top
Dickson
MM120 Dickson Alarm Thermometer
Take the cost out of temperature monitoring-- the most cost-effective
monitoring tool available. Easy-to-use features--
• Tamper-resistant audible/visual alarm
• Tracks Min/Max and current temperature
• One or two-probe options
• Glycol bottles for stable readings
• Easy-to-read LCD display
Note:This is an indicator, battery operated, stand alone system. No PCs
are required.
Temperature Range:
-58 to +122°F (-50 to 50°C)
Temperature Accuracy:
±1.8 over 0 to 122°F and ± 3.6 deg <0°F
Temperature Sensor:
Thermistor hard wired to PCB, submersible tip sealed in leak-proof glycol
bottle
Remote Probe Dimensions:
10ft
Alarm:
Yes- preset to 34 to 47F (MM120), preset to 34 to 47F and 6 to -20F
(MM125)
Alarm Type:
Audible/Visual Alarm
Ambient Operating Conditions:
Probe: -58 to +122°F (-50 to 50°C) 0 to 100% RH; Unit: +32 to
+122°F (0 to 50°C); 0 to 95% RH (non-condensing)
Approvals:
CE, ROHS
Battery Life (Avg):
1-Year (at 5-minute sample rate and no alarm conditions) - At Ambient
Conditions
Dimensions (Inches/cm):
4.6” x 2.75” x .8” (11.7cm x 7cm x 2cm)
Display:
yes
Display Dimensions:
1.9” Wide by 1” High
Display Resolution:
0.1°F (0.1°C)
Mounting:
Wall mount with keyhole or Velcro
Recording Times:
Continuous - Updates Min / Max stores only most current reading
Response Time:
30 seconds to 63% FS
Sample Interval:
Standard = 5 Min; Fast = 1 Min
Weight:
3.2oz unit only, 4.0oz unit with probe(s) and glycol bottle(s)
Included Accessories:
2 AA Batteries and Manual, Velcro for mounting, Certificate of Calibration;
MM120: 1 Probe in Glycol Bottle
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
Back to Top
Dickson
MM125 Dickson Alarm Thermometer with Two-Probes
Take the cost out of temperature monitoring-- the most cost-effective
monitoring tool available. Easy-to-use features--
• Tamper-resistant audible/visual alarm
• Tracks Min/Max and current temperature
• Two-probes
• Glycol bottles for stable readings
• Easy-to-read LCD display
Note:This is an indicator, battery operated, stand alone system. No PCs
are required.
Temperature Range:
-58 to +122°F (-50 to 50°C)
Temperature Accuracy:
±1.8 over 0 to 120°F and ± 3.6 deg <0°F
Temperature Sensor:
Thermistor hard wired to PCB, submersible tip sealed in leak-proof glycol
bottle
Remote Probe Dimensions:
10ft
Alarm:
yes
Alarm Type:
Audible/Visual Alarm
Ambient Operating Conditions:
Probe: -58 to +122°F (-50 to 50°C) 0 to 100% RH; Unit: +32 to
+122°F (0 to 50°C); 0 to 95% RH (non-condensing)
Approvals:
CE, ROHS
Battery Life (Avg):
1-Year (at 5-minute sample rate and no alarm conditions) - At Ambient
Conditions
Dimensions (Inches/cm):
4.6” x 2.75” x .8” (11.7cm x 7cm x 2cm)
Display:
yes
Display Dimensions:
1.9” Wide by 1” High
Display Resolution:
0.1°F (0.1°C)
Mounting:
Wall mount with keyhole or Velcro
Recording Times:
Continuous - Updates Min / Max stores only most current reading
Response Time:
30 seconds to 63% FS
Sample Interval:
Standard = 5 Min; Fast = 1 Min
Weight:
3.2oz (unit only)
Included Accessories:
2 AA Batteries and Manual, Velcro for mounting, Certificate of Calibration;
MM120: 2 Probe in Glycol Bottles
Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
Back to Top
Dickson
TC200 Spot-Check Handheld Temperature Indicator
Spot checks AND stores data-- takes the standard Digital thermometer to
the next level.
Designed for on-the-go quality managers--
• JUMBO display
• Delta T calculation of Temperature Changes
• Stores and recalls 16 readings
• Hold Key stores readings for later recall
• K-thermocouple probe
• User calibration
• Low battery indicator
Remote Temperature Range:
-300 to +1999°F (-184 to +1093°C) (using optional A203 K-TC
Probe)**-300 to +1650°F (-184 to +898°C)(using standard K-TC
Probe)
J Range:
-200 to +1400°F (-130 to +760°C)
K Range:
-300 to +1999°F (-184 to +1093°C)
T Range:
-250 to +750°F (-157 to +399°C)
Remote Temperature Accuracy:
Unit Only: ±0.2% of reading plus ±0.9°F (±0.5°C)
PLUS
K & J Probes: ±0.4% of reading above +32°F, ±0.2%
of reading below +32°F
OR
T Probe: ±0.4% of reading above +32°F, ±0.8% of reading
below +32°F
Remote Sensor:
K, J, or T Thermocouple
Ambient Operating Conditions:
+32 to +120°F (0 to +50°C), 0 to 95% RH (non-condensing)
Power Source:
One 9V battery (user replaceable)
Power Status Indicator:
LCD Display
Battery Life (Avg):
50-hours typical (auto shut-off after 12-minutes)
Display:
4 digit LCD with indicators
Display Resolution:
0.1° from 0.0 to 999.0; 1° above 1000 and below 0
Display Dimensions:
2" x 1.22" (51mm x 31mm)
Response Time:
10 seconds to full scale
Remote Probe Dimensions:
K-TC 5" Immersion Probe with 5'''' Coiled Cable.
Calibration:
Standard Dickson Certificate of Calibration
Available Calibration Options:
User: zero point; Factory: zero point and span NIST traceable
Approvals:
CE
Enclosure:
ABS & polycarbonate
Units / Pkg:
1
Dimensions (Inches/cm):
7.0x2.75x1.37
17.8x7.0x3.5
Weight:
11 oz
312g
Included Accessories:
K-Thermocouple probe shown & 9V battery
Warranty:
12-Month Limited
A.K.A.:
TC100, TC300, TC500, TC, Dickson TC, K-Thermocouple Indicator, K-TC
Indicator, Remote Probe Indicator, Remote Probe Hand Held, Thermocouple
Indicator, K-Thermocouple Hand Held, K-TC Hand Held, Thermocouple Hand
Held, J-Thermocouple Indicator, T-Thermocouple Indicator, Temperature
Indicator, Temperature Hand Held, Temperature Monitor
Accessories:
D617 K-Thermocouple 10' (3.05m) Straight Extension Cable
A202 K-Thermocouple 100' Straight Extension Cable
R013 Replacement Bead Wire Temperature Probe, K-Thermocouple; -300 to
500F (-184 to 260C)
D605 4" Piercing Temperature Probe, 5' Coiled Cable, +1650°F,
+900°C (316 Stainless Steel)
D608 5" Immersion Temperature Probe, 5' Coiled Cable, +1650°F,
900° (316 Stainless Steel)
A203 6" High Immersion Temperature Probe, 4.5' Straight Cable,
+2100°F, +1148°C (316 Stainless Steel)
A710 Carrying Case, Soft, Small
R007 9V Battery
Available Calibrations:
N100 NIST Traceable Calibration 1-pt. (Per New Unit)
N300 NIST Traceable Calibration 3-pt. (New Unit)
N400 A2LA Accredited Calibration 3-pt. (New Unit)
Back to Top
|